Inner Tube sort (Tying, Protection material of the Cable sort)
EXLON UL Tube
| |
Electrically insulating Vinyl tube made with UL and CSA standard. |
| |
Excellent in the heat resistance and the incombustibility. |
| |
Passed the Japan Electrical Appliance and Material Control Law combustibility test and bears the "F" mark. |
| |
Material : Soft Polyvinyl Chloride(PVC) under the Japan Electrical Appliance and Material Control Law. AHT-50-1 011CA0295 AHT-60-1 011CA0294 |
| |
Standard Color : TransparentBlack. |
|

|
Tube Surface Print For 300V -F-E56036, IWASE AH-3 CSA PVC 105C VW-1 For 600V -F-E56036, IWASE AH-6 CSA PVC 105C VW-1
| Size |
Dimension(mm) |
*AH-6 |
*AH-3 |
| Inner Diameter |
Tolerance |
Minimum Thickness (mm) |
Minimum Thickness (mm) |
| AWG24 |
0.55 |
±0.1 |
0.51 |
0.34 |
| 22 |
0.65 |
| 20 |
0.85 |
| 19 |
0.9 |
| 18 |
1.0 |
±0.15 |
| 17 |
1.2 |
0.56 |
| 16 |
1.3 |
| 15 |
1.5 |
| 14 |
1.7 |
| 13 |
1.9 |
±0.2 |
| 12 |
2.1 |
| 11 |
2.4 |
| 10 |
2.7 |
| 9 |
3.0 |
±0.25 |
0.44 |
| 8 |
3.3 |
| 7 |
3.7 |
| 6 |
4.2 |
±0.3 |
| 5 |
4.7 |
| 4 |
5.3 |
| 3 |
5.9 |
|
| Size |
Dimension(mm) |
*AH-6 |
*AH-3 |
| Minor Diameter |
Tolerance |
Minimum Thickness (mm) |
Minimum Thickness (mm) |
| 2 |
6.6 |
±0.3 |
0.56 |
0.44 |
| 1 |
7.4 |
±0.35 |
| 0 |
8.3 |
| 5/16" |
8.0 |
- |
| 6/16" |
9.5 |
| 7/16" |
11.1 |
| 8/16" |
12.7 |
| 9/16" |
14.3 |
±0.4 |
0.71 |
| 10/16" |
16.0 |
| 12/16" |
19.0 |
0.77 |
| 14/16" |
22.0 |
+0.7
-0.5 |
| 16/16" |
25.0 |
| 1-1/16" |
27.0 |
| 1-1/ 4" |
32.0 |
+1.0
-0.5 |
0.89 |
| 1-1/ 2" |
38.0 |
0.99 |
| 1-3/ 4" |
44.0 |
+1.5
-1.0 |
1.19 |
| 16/ 8" |
50.0 |
1.27 |
|
Red, blue, yellow, grey, brown, white, green, orange
are order products. (quantity ask separately.)
|
UL |
CSA |
| Approved Number |
E 56036 |
LR 33763 |
| Rated Temperature |
105°C |
105°C |
| Rated Voltage |
300V(AH-3) 600V(AH-6) |
300V(AH-3) 600V(AH-6) |
| Incombustibility |
VW-1 |
VW-1 |
|
|